With the advancement of technology, swimming pool heat pumps are gradually entering places such as swimming pools and hotels. However, many customers do not know how to install and use swimming pool electric heat pump after purchasing them from professional air energy heat pump manufacturers. So, Finney will provide detailed installation methods and daily maintenance for the pool heat pump to solve installation problems for everyone.


The installation method of a above ground swimming pool heat pump mainly includes two parts: the installation of a swim pool heat pump unit and the installation of a pool water system.


Four major precautions for installing a heat pump for above ground swimming pool unit:


1. When the unit is equipped with side air intake, the distance between the air intake surface and the wall shall not be less than 1 meter. When the metal covers of two units are arranged opposite, the distance between them shall not be less than 1.5 meters;

2. Measures should be taken to eliminate a large amount of condensed water generated by the unit at the location where the unit is set up;

3. Only one side of the partition wall around the unit is allowed to be higher than the unit height;

4. The foundation height of the unit should not be less than 300mm and greater than the local snow thickness;


Eight suggestions for installing the swimming pool water system


1. Install the air energy heat pump pool unit downstream of all filtration devices and pool pumps, and upstream of all chlorine generators, ozone generators, and chemical disinfection.

2. In general, the air source heat pump swimming pool unit should be installed within 7.5 meters of the swimming pool, and if the swimming pool water pipe is too long, it is recommended to wrap a 10mm thick insulation pipe to avoid insufficient heating due to excessive heat loss of the unit;

3. The design of the water system requires the installation of a union on the inlet and outlet water of the heat pump to facilitate winter drainage;

4. Try to shorten the water pipeline as much as possible, avoid or reduce unnecessary pipeline changes, to reduce resistance loss, and install an exhaust pipe at the highest position of the water main pipeline to facilitate timely evacuation of gas in the water pipeline; Install a drain valve at the lowest point of the system to facilitate drainage during system cleaning;

5. The water system must be equipped with pumps with appropriate flow and head to ensure that the water flow meets the needs of the unit. How to choose a suitable flow and head water pump?

6. During the operation of the heat pump, the air temperature will decrease by about 5 degrees, and condensation water will be generated on the evaporator fins and fall onto the chassis, which will be discharged through the plastic drain nozzle installed on the chassis. This is a normal phenomenon (condensation water is easily mistaken for water leakage in the heat pump water system), and drainage pipes must be installed to timely drain the condensation water during installation;

7. Do not connect the tap water pipe or other water pipes to the circulating pipeline to avoid damage to the circulating pipeline and heat pump unit;

8. The water tank of the hot water heating system needs to have good insulation performance. Do not install the water tank in a place with contaminated and corrosive gases;


After installing the air powered swimming pool heat pump, achieving the durability of the swimming pool heat pump requires the user's regular maintenance and upkeep. Therefore, it is crucial to do a good job in the daily maintenance and upkeep of the pool heat pump, and it cannot be ignored. So how to do a good job in repairing and maintaining the pool heat pump?


Daily maintenance and upkeep of swimming pool heat pumps


1. All safety protection devices in the swimming pool heat pump are set before leaving the factory, and do not adjust them on your own;

2. Regularly check the operation of various components of the swimming pool heat pump, check for oil stains at the pipeline joints and inflation valves inside the swimming pool heat pump, and ensure that there is no refrigerant leakage;

3. Regularly check whether the circulating water pump, water circuit valves are working properly, and whether the water pipeline and water pipe joints are leaking;

4. If the air source heat pump for swimming pool has been shut down for a long time, the water in the unit pipeline should be drained, the power should be cut off, the protective cover should be put on, and a comprehensive inspection of the system should be carried out before starting up;

5. Regularly check whether the power supply and electrical system wiring of the swimming pool heat pump are secure, and whether there are any abnormalities in the electrical components. If there are any, they should be repaired or replaced in a timely manner;


CONTACT US

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!