Availability: | |
---|---|
| |
● WIDE OPERATING RANGE
T3 Swimming Pool Heat Pump have wide working ambient temperature range. It means that heat pump working range is from -5°C to 52°C.
● HIGHER EFFICIENT: HEATING/COOLING
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
● HIGH COP
The COP is as high as 5.47 which is even higher than the first class energy level.
● HIGH COP
Using corrosion proof titanium heat exchanger, and greatly resist erosion of chlorine ion in water, solid and durable, no harm to human body. |
● REVERSE CYCLE DEFROSTING
The four-way valve defrosting technology of LC side descharge pool heat pump can automatically start defrosting according to the ambient temperature, plus a specially designed chasis with two drainage holes, the unit always runs in high efficiency.
● MULTIPLE SYSTEM PROTECTIONS
To guarantee the stable running of the unit, multiple protection devices have been implemented which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection.
● WIDE OPERATING RANGE
T3 Swimming Pool Heat Pump have wide working ambient temperature range. It means that heat pump working range is from -5°C to 52°C.
● HIGHER EFFICIENT: HEATING/COOLING
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
● HIGH COP
The COP is as high as 5.47 which is even higher than the first class energy level.
● HIGH COP
Using corrosion proof titanium heat exchanger, and greatly resist erosion of chlorine ion in water, solid and durable, no harm to human body. |
● REVERSE CYCLE DEFROSTING
The four-way valve defrosting technology of LC side descharge pool heat pump can automatically start defrosting according to the ambient temperature, plus a specially designed chasis with two drainage holes, the unit always runs in high efficiency.
● MULTIPLE SYSTEM PROTECTIONS
To guarantee the stable running of the unit, multiple protection devices have been implemented which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection.
Model | LCSPC-150M | LCSPC-190M | LCSPC-250M | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 50,000 | 65,000 | 85,000 |
power input (kW) | 2.37 | 2.97 | 4.12 | |
COP | 6.17 | 6.40 | 6.04 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 46,500 | 55,500 | 80,000 |
power input (kW) | 2.31 | 2.71 | 4.04 | |
COP | 5.93 | 6.01 | 5.8 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 30,000 | 35,000 | 56,000 |
power input (kW) | 2.15 | 2.32 | 4.1 | |
COP | 4.0 | 4.40 | 4.0 | |
Power supply | V/PH/Hz | AC 208-240/1/60Hz | ||
Max current | A | 16.7 | 24.6 | 32.18 |
Compressor type | Rotary | Rotary | Scroll | |
Refrigerant volume | R410A | R410A | R410A |
Model | LCSPC-150M | LCSPC-190M | LCSPC-250M | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 50,000 | 65,000 | 85,000 |
power input (kW) | 2.37 | 2.97 | 4.12 | |
COP | 6.17 | 6.40 | 6.04 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 46,500 | 55,500 | 80,000 |
power input (kW) | 2.31 | 2.71 | 4.04 | |
COP | 5.93 | 6.01 | 5.8 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 30,000 | 35,000 | 56,000 |
power input (kW) | 2.15 | 2.32 | 4.1 | |
COP | 4.0 | 4.40 | 4.0 | |
Power supply | V/PH/Hz | AC 208-240/1/60Hz | ||
Max current | A | 16.7 | 24.6 | 32.18 |
Compressor type | Rotary | Rotary | Scroll | |
Refrigerant volume | R410A | R410A | R410A |