Looking for an energy-efficient and cost-effective solution to heat your swimming pool in Dubai? Look no further than our Swimming Pool Heat Pump! Equipped with advanced heat pump technology, our product provides reliable heating year-round, regardless of outdoor temperatures. The T3 model is designed with a top fan, which enhances the unit's efficiency and performance, and a sleek domestic casing that can withstand harsh weather and corrosive environments. With our heat pump, you can enjoy your pool to the fullest, no matter the season, while also saving on energy costs. Upgrade your swimming pool experience today with our commercial pool chiller!
Lailey monoblock air source swimming pool heat pumps are designed for pool water heating and cooling with max outlet water temperature 40℃. They have the following important features:
Absorb heat from the air with high COP (up to 5.16);
Pool Water heating and cooling function available;
Constant pool water temperature (max 40℃);
Working air temperature range: -10℃ to 45℃;
Anti-corrosion with Titanium Tube-in-shell Heat Exchanger;
Automatic and forced defrosting function;
Guaranteed safety: water and electricity are isolated;
Save 65%-80% of the operating costs without pollution to the environment.
LAILY Heat Pump Specification(Heat&Chill)
Air source swimming pool heat pump for swimming pool,spa heating and cooling
heating capacity 40kw, 50kw 60kw option
Model | LCSP-400 | LCSP-500 | LCSP-600 | |
Ambient 24 ℃ Water 26℃ in, 28 ℃ out | Capacity (kW) | 42.21 | 52.32 | 60.70 |
power input (kW) | 8.07 | 9.93 | 11.10 | |
COP | 5.23 | 5.27 | 5.47 | |
Ambient 15 ℃ Water 26℃ in, 28 ℃ out | Capacity (kW) | 36.03 | 44.93 | 51.54 |
power input (kW) | 8.01 | 9.91 | 10.64 | |
COP | 4.50 | 4.53 | 4.84 | |
Ambient 35 ℃ Water 29℃ in, 27 ℃ out | Capacity (kW) | 32.10 | 34.98 | 37.54 |
power input (kW) | 10.07 | 12.81 | 13.04 | |
EER | 3.19 | 2.73 | 2.88 | |
Working Ambient Temerature | ℃ | -10~43 | -10~43 | -10~43 |
Power Supply | 380-415V/3N/50Hz | 380-415V/3N/50Hz | 380-415V/3N/50Hz | |
Max Power Input | kW | 11.65 | 14.12 | 16.22 |
Max Current | A | 17.71 | 22.92 | 24.66 |
Compressor Type | Scroll | Scroll | Scroll | |
Fan Direction | Vertical | Vertical | Vertical | |
Water Flow Volume | m3/h | 18.15 | 22.53 | 25.05 |
Refrigerant Type | R410A | R410A | R410A | |
Min Pressure/Max Pressure | 1.5/4.15Mpa | 1.5/4.15Mpa | 1.5/4.15Mpa | |
Material of Casing | Galvanized steel | Galvanized steel | Galvanized steel | |
Unit Net Dimensions(L*W*H) | mm | 1520*738*1132 | 1520*738*1132 | 1520*738*1132 |
Net Weight | kg | 260 | 280 | 340 |
Gross Weight | kg | 290 | 310 | 370 |
Sound Pressure 1m | dB(A) | 61 | 61 | 61 |
Water proof level | IPX4 | IPX4 | IPX4 |
● WIDE OPERATING RANGE
T3 Swimming Pool Heat Pump have wide working ambient temperature range. It means that heat pump working range is from -5°C to 52°C.
● HIGHER EFFICIENT: HEATING/COOLING
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
● HIGH COP
The COP is as high as 5.47 which is even higher than the first class energy level.
● HIGH COP
Using corrosion proof titanium heat exchanger, and greatly resist erosion of chlorine ion in water, solid and durable, no harm to human body. | |
● REVERSE CYCLE DEFROSTING
LAILEY commercial pool heat pump with the four-way valve defrosting technology can automatically start defrosting according to the ambient temperature, plus a specially designed chasis with two drainage holes, the unit always runs in high efficiency.
● MULTIPLE SYSTEM PROTECTIONS
To guarantee the stable running of the unit, multiple protection devices have been implemented which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection.
Heat pump Certificates
Our heat pump products and factory has passed multiple international certifications.
LAILEY Swimming Pool Heaters models series
Model | LCSPC-150M | LCSPC-190M | LCSPC-250M | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 50,000 | 65,000 | 85,000 |
power input (kW) | 2.37 | 2.97 | 4.12 | |
COP | 6.17 | 6.40 | 6.04 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 46,500 | 55,500 | 80,000 |
power input (kW) | 2.31 | 2.71 | 4.04 | |
COP | 5.93 | 6.01 | 5.8 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 30,000 | 35,000 | 56,000 |
power input (kW) | 2.15 | 2.32 | 4.1 | |
COP | 4.0 | 4.40 | 4.0 | |
Power supply | V/PH/Hz | AC 208-240/1/60Hz | ||
Max current | A | 16.7 | 24.6 | 32.18 |
Compressor type | Rotary | Rotary | Scroll | |
Refrigerant volume | R410A | R410A | R410A |