Upgrade your in-ground swimming pool with our Top Fan Air to Water In-ground Pool Heat Pump, designed for the Middle East market! Our product utilizes advanced heat pump technology to provide efficient and reliable heating for your in-ground pool year-round, regardless of outdoor temperatures. With a top fan design, our unit maximizes its performance and efficiency, while the sleek casing can withstand harsh weather conditions and corrosive environments. Our air to water heat pump extracts heat from the air and transfers it to the water, providing consistent and cost-effective heating for your in-ground pool. With our product, you can enjoy your pool to the fullest, no matter the season, while also saving on energy costs. Upgrade your in-ground swimming pool experience today with our Top Fan Air to Water In-ground Pool Heat Pump!
● WIDE OPERATING RANGE
T3 Swimming Pool Heat Pump have wide working ambient temperature range. It means that heat pump working range is from -5°C to 52°C.
● HIGHER EFFICIENT: HEATING/COOLING
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
● HIGH COP
The COP is as high as 5.47 which is even higher than the first class energy level.
● HIGH COP
Using corrosion proof titanium heat exchanger, and greatly resist erosion of chlorine ion in water, solid and durable, no harm to human body. | |
● REVERSE CYCLE DEFROSTING
The four-way valve defrosting technology of LC side descharge pool heat pump can automatically start defrosting according to the ambient temperature, plus a specially designed chasis with two drainage holes, the unit always runs in high efficiency.
● MULTIPLE SYSTEM PROTECTIONS
To guarantee the stable running of the unit, multiple protection devices have been implemented which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection.
Model | LCSPC-150M | LCSPC-190M | LCSPC-250M | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 50,000 | 65,000 | 85,000 |
power input (kW) | 2.37 | 2.97 | 4.12 | |
COP | 6.17 | 6.40 | 6.04 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 46,500 | 55,500 | 80,000 |
power input (kW) | 2.31 | 2.71 | 4.04 | |
COP | 5.93 | 6.01 | 5.8 | |
Ambient 80℉, Inlet water 80℉ 80% Relative Humidity | Capacity (Btu/h) | 30,000 | 35,000 | 56,000 |
power input (kW) | 2.15 | 2.32 | 4.1 | |
COP | 4.0 | 4.40 | 4.0 | |
Power supply | V/PH/Hz | AC 208-240/1/60Hz | ||
Max current | A | 16.7 | 24.6 | 32.18 |
Compressor type | Rotary | Rotary | Scroll | |
Refrigerant volume | R410A | R410A | R410A |